Products
Part Number | Nominal Size(mm) | busbar dimension | As supplied (mm) | After recovered (mm) | Applicable busbar dimension (mm) | Standard Length (Meter) | ||
---|---|---|---|---|---|---|---|---|
I.D.(min) (D) | I.D.(max) (d) | W.T. (w) | L+T (min)(max) | R(min)(max) | ||||
HB1-020 | 20 | 20x3 | 20 | 10 | 0.80±0.15 | 19~24 | 12.0~15.0 | 100 |
HB1-030 | 30 | 30x3 30x4 | 30 | 15 | 0.90±0.15 | 27~39 | 17.0~25.0 | 50 |
HB1-040 | 40 | 30x10 40x4 | 40 | 20 | 1.00±0.15 | 36~47 | 23.0~30.0 | 50 |
HB1-050 | 50 | 40x10 50x5 50x6 |
50 | 25 | 1.00±0.15 | 44~68 | 28.0~43.0 | 25 |
HB1-060 | 60 | 50x8 50x10 60x6 60x8 |
60 | 30 | 1.55±0.20 | 52~86 | 33.0~55.0 | 25 |
HB1-070 | 70 | 60x10 | 70 | 35 | 1.60±0.25 | 60~102 | 38.0~65.0 | 25 |
HB1-080 | 80 | 60x10 80x10 | 80 | 40 | 1.70±0.25 | 68~118 | 43.0~75.0 | 25 |
HB1-090 | 90 | 100x10 | 90 | 45 | 1.70±0.25 | 75~129 | 48.0~82.0 | 25 |
HB1-100 | 100 | 100x8 100x10 100x12 |
100 | 50 | 1.80±0.30 | 86~141 | 55.0~90.0 | 25 |
HB1-120 | 120 | 100x15 120x10 120x12 120x15 |
120 | 60 | 1.90±0.30 | 104~172 | 66.0~110.0 | 15 |
HB1-150 | 150 | 150x12 150x15 | 150 | 75 | 1.90±0.30 | MAX | 15 | |
HB1-180 | 180 | 150x10 150x20 | 180 | 90 | 2.10±0.30 | MAX | 15 |
Property | Specification Requirement | Test Method | Typical Value |
---|---|---|---|
Longitudinal change | -10%~10% | ASTM D2671 | Pass |
Tensile strength | ≥10.3Mpa | ASTM D638 | ≥11.3Mpa |
Tensile strength after aging | 70% of initial value | ASTM D638 (158˚C/168 hrs) |
≥80% |
Elongation at break | ≥200% | ASTM D638 | ≥400% |
Elongation at break after aging | ≥100% | ASTM D638 (158˚C/168 hrs) |
≥200% |
Low temperature flexibility | No cracking | ASTM D2671 (-30˚C/1 hr) |
No cracking |
Volume resistivity | ≥1014Ω.cm | ASTM D876 | ≥1014Ω.cm |
Dielectric voltage withstand | AC2500V/60S No breakdown |
ASTM D2671 | No breakdown |
Flammability | VW-1 | UL224 | Pass |